{"created":"2023-03-31T02:40:09.863484+00:00","id":5717,"links":{},"metadata":{"_buckets":{"deposit":"6050786d-92e2-4585-8698-3eda5841fda0"},"_deposit":{"id":"5717","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"5717"},"status":"published"},"_oai":{"id":"oai:nied-repo.bosai.go.jp:00005717","sets":[]},"author_link":[],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"66","bibliographicPageEnd":"649","bibliographicPageStart":"644","bibliographicVolumeNumber":"27","bibliographic_titles":[{"bibliographic_title":"日本建築学会技術報告集","bibliographic_titleLang":"ja"},{"bibliographic_title":"AIJ Journal of Technology and Design","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"

This paper proposes a simple mechanical on-off damper that can change the damping force depending on the response displacement and response velocity. The on-off damper reduces the damage to seismic-isolated structures that undergo excessive deformation during huge earthquakes, without lowering the performance of the seismic-isolation system during design earthquakes. A numerical analysis method for base-isolated structures in which the isolation layer is equipped with our on-off damper, and also considers collisions with stoppers, is expatiated. A shaking table experiment was conducted, and the results were compared with the numerical analyses. The test results agree approximately with the numerical analysis results.

","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"

This paper proposes a simple mechanical on-off damper that can change the damping force depending on the response displacement and response velocity. The on-off damper reduces the damage to seismic-isolated structures that undergo excessive deformation during huge earthquakes, without lowering the performance of the seismic-isolation system during design earthquakes. A numerical analysis method for base-isolated structures in which the isolation layer is equipped with our on-off damper, and also considers collisions with stoppers, is expatiated. A shaking table experiment was conducted, and the results were compared with the numerical analyses. The test results agree approximately with the numerical analysis results.

","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本建築学会","subitem_publisher_language":"ja"},{"subitem_publisher":"Architectural Institute of Japan","subitem_publisher_language":"en"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3130/aijt.27.644"}}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1341-9463","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"岸田 明子","creatorNameLang":"ja"},{"creatorName":"KISHIDA Akiko","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"多賀 謙蔵","creatorNameLang":"ja"},{"creatorName":"TAGA Kenzo","creatorNameLang":"en"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_title":"免震建物における極大地震動対策のための簡易な減衰力切り替え機構を有するダンパーの開発","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"免震建物における極大地震動対策のための簡易な減衰力切り替え機構を有するダンパーの開発","subitem_title_language":"ja"},{"subitem_title":"DEVELOPMENT OF SIMPLE MECHANICAL ON-OFF DAMPER FOR BASE-ISOLATED BUILDINGS SUBJECTED EXTREME EARTHQUAKES","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"1","path":["1670839190650"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2023-03-30"},"publish_date":"2023-03-30","publish_status":"0","recid":"5717","relation_version_is_last":true,"title":["免震建物における極大地震動対策のための簡易な減衰力切り替え機構を有するダンパーの開発"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-06-08T09:28:53.556844+00:00"}