{"created":"2024-06-03T02:00:43.952526+00:00","id":6662,"links":{},"metadata":{"_buckets":{"deposit":"b9d94758-f466-4fea-9787-6403cb227619"},"_deposit":{"created_by":10,"id":"6662","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"6662"},"status":"published"},"_oai":{"id":"oai:nied-repo.bosai.go.jp:00006662","sets":[]},"author_link":[],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1997","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"4","bibliographicPageEnd":"336","bibliographicPageStart":"329","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"水文・水資源学会誌","bibliographic_titleLang":"ja"},{"bibliographic_title":"JOURNAL OF JAPAN SOCIETY OF HYDROLOGY AND WATER RESOURCES","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"1996年8月に銀座オフィス街において,都市上空の熱収支特性に関する観測を行った.渦相関法とシンチレーション法を併用した計測により,以下の結果を得た.1)銀座オフィス街での熱収支の実態を明らかにし,顕熱・潜熱・蓄熱が同程度の割合で寄与していることを明らかにした.2)都市は顕熱に匹敵する『人工的な潜熱』を出しており,原因として冷房による潜熱放出が有力な候補であることを示した.3)建物側面の窓などからの蓄熱量は無視できない大きさであり,休日の人工熱及び潜熱は平日より少なかった.4)シンチレーション法によるキャノピー上端の顕熱量は,渦相関法によるビル屋上の顕熱とほぼ一致し,ビル屋上での計測の代表性が確認された.4)都市キャノピーにおけるシンチロメータの利用に際しては,ゼロ面変位の算定が重要であることを示し,その決定手法を提案した.","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"The field observations were performed in Ginza office area in summer 1996, to investigate the characteristics of heat balance in complicated urban canopies. The sensible heat was measured by two methods, one was “eddy correlation method” and another was “scintillation method”. The following results were obtained; 1) The observed latent heat flux was very large and comparable to the sensible heat flux. This was proved to be caused by cooling systems introduced to office buildings. 2) The artificial and latent heat on a holiday were less than those on a weekday. 3) The sensible heat observed by scintillation technique agreed well with that by the eddy correlation method. And also, the longer measure ment path of scintillation meter (130m in this case) compared to that of sonic anemometer (only 15cm) could make the fluctuations smaller. 4) The displacement height (d) was found to be very sensitive to the results of scintillation methods and the way how to determine it was discussed.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"水文・水資源学会","subitem_publisher_language":"ja"},{"subitem_publisher":"THE JAPAN SOCIETY OF HYDROLOGY AND WATER RESOURCES","subitem_publisher_language":"en"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3178/jjshwr.10.329"}}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0915-1389","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"神田 学","creatorNameLang":"ja"},{"creatorName":"KANDA Manabu","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"高柳 百合子","creatorNameLang":"ja"},{"creatorName":"TAKAYANAGI Yuriko","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"横山 仁","creatorNameLang":"ja"},{"creatorName":"YOKOYAMA Hitoshi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"森脇 亮","creatorNameLang":"ja"},{"creatorName":"MORIWAKI Ryo","creatorNameLang":"en"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_title":"銀座オフィスビル街における熱収支特性","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"銀座オフィスビル街における熱収支特性","subitem_title_language":"ja"},{"subitem_title":"Field Observation of the Heat Balance in an Urban Area.","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"10","path":["1670839190650"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-06-03"},"publish_date":"2024-06-03","publish_status":"0","recid":"6662","relation_version_is_last":true,"title":["銀座オフィスビル街における熱収支特性"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2024-06-03T02:01:08.828299+00:00"}