{"created":"2024-08-05T01:33:52.271976+00:00","id":6723,"links":{},"metadata":{"_buckets":{"deposit":"67e2c350-1c7f-4153-b2a6-e522088983be"},"_deposit":{"created_by":10,"id":"6723","owners":[10],"pid":{"revision_id":0,"type":"depid","value":"6723"},"status":"published"},"_oai":{"id":"oai:nied-repo.bosai.go.jp:00006723","sets":[]},"author_link":[],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-07","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"809","bibliographicPageEnd":"1123","bibliographicPageStart":"1116","bibliographicVolumeNumber":"88","bibliographic_titles":[{"bibliographic_title":"Journal of Structural and Construction Engineering","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This study reports the relationship between the movement of medical equipment and near-fault and long-period-long-duration earthquake ground motions, aiming to provide practitioners and researchers with criteria for limiting disorder and functional deterioration during earthquakes. The influence of floor sheeting materials on the rolling friction coefficients of the equipment’s casters and their resistance to move out of floor dents was evaluated at a pulling test. Then, the seismic behavior of medical equipment was evaluated at E-Defense shaking table tests where a group of critical equipment was arranged for department rooms in the full-scale earthquake-resistant and seismically-isolated steel frames.","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_10001_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.3130/aijs.88.1116"}}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1881-8153","subitem_source_identifier_type":"EISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Masahiro Kurata","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Motoki Akazawa","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Shinji Aida","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kosai Cho","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Yohsuke Kawamata","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Kazuhiro Saburi","creatorNameLang":"en"}]},{"creatorNames":[{"creatorName":"Shigeru Ohtsuru","creatorNameLang":"en"}]}]},"item_title":"SEISMIC BEHAVIOR OF MEDICAL EQUIPMENT IN EARTHQUAKE-RESISTANT AND SEISMICALLY-ISOLATED BUILDINGS AT E-DEFENSE SHAKING TABLE TESTS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"SEISMIC BEHAVIOR OF MEDICAL EQUIPMENT IN EARTHQUAKE-RESISTANT AND SEISMICALLY-ISOLATED BUILDINGS AT E-DEFENSE SHAKING TABLE TESTS","subitem_title_language":"en"}]},"item_type_id":"40001","owner":"10","path":["1670839190650"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2024-08-05"},"publish_date":"2024-08-05","publish_status":"0","recid":"6723","relation_version_is_last":true,"title":["SEISMIC BEHAVIOR OF MEDICAL EQUIPMENT IN EARTHQUAKE-RESISTANT AND SEISMICALLY-ISOLATED BUILDINGS AT E-DEFENSE SHAKING TABLE TESTS"],"weko_creator_id":"10","weko_shared_id":-1},"updated":"2024-08-05T01:33:53.647525+00:00"}