@misc{oai:nied-repo.bosai.go.jp:00007143, author = {防災科学技術研究所 and National Research Institute for Earth Science and Disaster Resilience}, month = {}, note = {E-ディフェンスの本格運用に先立ち,試験体搭載時の震動台の応答および性能確認,計測系システムの性能確認などを目的とした確認試験を実施しました。試験体として,幅12m,奥行き9m,高さ20mの5層鉄骨フレーム建物を作製して,1995年兵庫県南部地震で観測された地震動などを入力しました。その結果,震動台の応答は,試験体の共振の影響を受けますが,入力地震動を調整することにより,その影響を低減できることなどが明らかとなっています。, Prior to the fully operational use of E-Defense, verification tests were conducted to confirm the response and performance of the shaking table and the measurement system when the full-scale test specimen was mounted on it. A five-story steel frame building 12 m wide, 9 m deep, and 20 m high was constructed as the test specimen, and seismic motions observed during the 1995 Southern Hyogo Prefecture Earthquake were input. As a result, it was found that the response of the shake table is affected by the resonance of the specimen, but this effect can be reduced by adjusting the input seismic motion., データ取得:2005年, Data acquisition period : 2005, お問い合わせ:asebi@bosai.go.jp, inquiry: asebi@bosai.go.jp}, title = {標準試験体を用いたE-ディフェンスの応答確認実験}, year = {2007}, yomi = {ボウサイカガクギジュツケンキュウショ} }