{"created":"2025-06-13T01:58:37.304272+00:00","id":7171,"links":{},"metadata":{"_buckets":{"deposit":"02328c9c-0913-491e-bd04-5f662c0ed339"},"_deposit":{"created_by":7,"id":"7171","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"7171"},"status":"published"},"_oai":{"id":"oai:nied-repo.bosai.go.jp:00007171","sets":["5:1749778844647"]},"author_link":["1632"],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"鉄骨造建物実験研究 制振構造建物実験","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Five-story Steel Building with Supplemental Dampers","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"防災科学技術研究所","creatorNameLang":"ja"},{"creatorName":"ボウサイカガクギジュツケンキュウショ","creatorNameLang":"ja-Kana"},{"creatorName":"National Research Institute for Earth Science and Disaster Resilience","creatorNameLang":"en"}],"familyNames":[{"familyName":"防災科学技術研究所","familyNameLang":"ja"},{"familyName":"ボウサイカガクギジュツケンキュウショ","familyNameLang":"ja-Kana"},{"familyName":"National Research Institute for Earth Science and Disaster Resilience","familyNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1632","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"DA04781797","nameIdentifierScheme":"CiNii","nameIdentifierURI":"https://ci.nii.ac.jp/author/DA04781797"}]}]},"item_1617186626617":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"いまだ経験のない大地震下での制振装置付き建物の性能を検証することを目的として、E-ディフェンスを用いた制振部材を有する実大5層鉄骨造建物の加振実験を行いました。です。制振装置としてブレース型ダンパーを用い、鋼材・粘性・オイル・粘弾性・なしの順に取り替えながら加振を行いました。試験体は、事務所ビルを想定したものであり、可能な限り実際に近い建物とするため、非構造部材も設置しました。加振には、1995年兵庫県南部地震で観測されたJR鷹取波を様々なレベルで用い、試験体の応答を検証しました。","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"With the aim of verifying the performance of buildings with vibration control devices under conditions of a major earthquake, which has not yet been experienced, a shaking table test was conducted on a full-scale 5-story steel frame building with dampers using the E-Defense shaking table. The test was conducted using a brace-type damper as the vibration control device, and the steel, viscous, oil, visco-elastic, and non-viscous dampers were replaced in that order. The test specimen was designed to resemble an office building, and non-structural members were also installed to make it as close to an actual building as possible. The JR Takatori ground motion observed during the 1995 Southern Hyogo Prefecture Earthquake was used at various levels to verify the response of the test specimen.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"データ取得:2009年 ","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"Data acquisition period : 2009","subitem_description_language":"en","subitem_description_type":"Other"},{"subitem_description":"お問い合わせ:asebi@bosai.go.jp ","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"inquiry: asebi@bosai.go.jp","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"防災科学技術研究所"},{"subitem_1522300295150":"en","subitem_1522300316516":"National Research Institute for Earth Science and Disaster Resilience"}]},"item_1617186660861":{"attribute_name":"Date","attribute_value_mlt":[{"subitem_1522300695726":"Issued","subitem_1522300722591":"2011"}]},"item_1617186783814":{"attribute_name":"識別子","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"10.17598/NIED.0020-E200807"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"dataset","resourceuri":"http://purl.org/coar/resource_type/c_ddb1"}]},"item_1617353299429":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_1522306207484":"isIdenticalTo","subitem_1522306287251":{"subitem_1522306382014":"URI","subitem_1522306436033":"https://asebi.bosai.go.jp/"},"subitem_1523320863692":[{"subitem_1523320867455":"en","subitem_1523320909613":"LOGIN Page for Registered Users"}]}]},"item_title":"鉄骨造建物実験研究 制振構造建物実験","item_type_id":"40006","owner":"7","path":["1749778844647"],"publish_date":"2025-06-19","publish_status":"0","recid":"7171","relation_version_is_last":true,"title":["鉄骨造建物実験研究 制振構造建物実験"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2025-06-23T05:38:51.585943+00:00"}