{"created":"2025-06-13T01:58:40.992949+00:00","id":7174,"links":{},"metadata":{"_buckets":{"deposit":"69418080-05bd-4cdc-b3f9-39d6cad3a623"},"_deposit":{"created_by":7,"id":"7174","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"7174"},"status":"published"},"_oai":{"id":"oai:nied-repo.bosai.go.jp:00007174","sets":["5:1749778844647"]},"author_link":["1632"],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"NEESWoodプロジェクト『木質パネル構法7階建て』実大建物実験","subitem_1551255648112":"ja"},{"subitem_1551255647225":"NEES Wood Project “7-story Building using Wooden Panel Construction Method” Experiment of Full-scale Building","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"防災科学技術研究所","creatorNameLang":"ja"},{"creatorName":"ボウサイカガクギジュツケンキュウショ","creatorNameLang":"ja-Kana"},{"creatorName":"National Research Institute for Earth Science and Disaster Resilience","creatorNameLang":"en"}],"familyNames":[{"familyName":"防災科学技術研究所","familyNameLang":"ja"},{"familyName":"ボウサイカガクギジュツケンキュウショ","familyNameLang":"ja-Kana"},{"familyName":"National Research Institute for Earth Science and Disaster Resilience","familyNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1632","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"DA04781797","nameIdentifierScheme":"CiNii","nameIdentifierURI":"https://ci.nii.ac.jp/author/DA04781797"}]}]},"item_1617186626617":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"防災科学技術研究所はNEES(The George E. Brown, Jr. Network for Earthquake Engineering Simulation)との国際共同研究の一環として、NEESで主に木造建物を研究するNEESWOOD (プロジェクトリーダー:John W. van de Lindt教授 コロラド州立大学) と7階建て木造建物実験を行いました。 試験体は1階(地下駐車場を想定)のみ鉄骨造、2-7階は枠組壁工法で建設された木造建物です。試験体の大きさは、縦横が約12.4 m x 18.4 m、高さ20.4 mです。 実験は、1994年Northridge地震のCanoga Parkで記録された加速度波形の振幅を180%に調整した波形で加振を行い、建物の強震時における応答を確認しました。","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"As a part of international collaborative research of NIED and the George E. Brown, Jr. Network for Earthquake Engineering Simulation (NEES), a shaking table experiment on a full-scale 7-story wood building was conducted by NEESWood, which is responsible for study in wood structure at NEES, (PI: Professor John W. van de Lindt, Colorado State University) and NIED. The first story of the test structure was a steel frame simulating a basement parking area. The 2nd to 7th stories were the residential area constructed by the wood-frame structure. The test structure was 12.4 m wide, 18.4 m long and 20.4 m high. In the experiment, the seismic motion recorded at Canoga Park during 1994 Northridge earthquake was used. The test structure was shaken by the 180% of the seismic motion, and the response of the structure under the severe input motion was investigated.","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"データ取得:2009年 ","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"Data acquisition period : 2009","subitem_description_language":"en","subitem_description_type":"Other"},{"subitem_description":"お問い合わせ:asebi@bosai.go.jp ","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"inquiry: asebi@bosai.go.jp","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"防災科学技術研究所"},{"subitem_1522300295150":"en","subitem_1522300316516":"National Research Institute for Earth Science and Disaster Resilience"}]},"item_1617186660861":{"attribute_name":"Date","attribute_value_mlt":[{"subitem_1522300695726":"Issued","subitem_1522300722591":"2011"}]},"item_1617186783814":{"attribute_name":"識別子","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"10.17598/NIED.0020-E200903"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"dataset","resourceuri":"http://purl.org/coar/resource_type/c_ddb1"}]},"item_1617353299429":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_1522306207484":"isIdenticalTo","subitem_1522306287251":{"subitem_1522306382014":"URI","subitem_1522306436033":"https://asebi.bosai.go.jp/"},"subitem_1523320863692":[{"subitem_1523320867455":"en","subitem_1523320909613":"LOGIN Page for Registered Users"}]}]},"item_title":"NEESWoodプロジェクト『木質パネル構法7階建て』実大建物実験","item_type_id":"40006","owner":"7","path":["1749778844647"],"publish_date":"2025-06-19","publish_status":"0","recid":"7174","relation_version_is_last":true,"title":["NEESWoodプロジェクト『木質パネル構法7階建て』実大建物実験"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2025-06-23T05:38:52.673457+00:00"}