{"created":"2025-06-13T02:00:15.029648+00:00","id":7233,"links":{},"metadata":{"_buckets":{"deposit":"41e0f3fe-bbc1-4940-b52b-d256de2d97e5"},"_deposit":{"created_by":7,"id":"7233","owners":[7],"pid":{"revision_id":0,"type":"depid","value":"7233"},"status":"published"},"_oai":{"id":"oai:nied-repo.bosai.go.jp:00007233","sets":["5:1749778844647"]},"author_link":["1632"],"item_1617186331708":{"attribute_name":"Title","attribute_value_mlt":[{"subitem_1551255647225":"60tテストベッドによる浮揚式3次元免震装置の加振実験","subitem_1551255648112":"ja"},{"subitem_1551255647225":"Shake Table Test of Floating Base-isolation Device using 60-ton Test Bed","subitem_1551255648112":"en"}]},"item_1617186419668":{"attribute_name":"作成者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"防災科学技術研究所","creatorNameLang":"ja"},{"creatorName":"ボウサイカガクギジュツケンキュウショ","creatorNameLang":"ja-Kana"},{"creatorName":"National Research Institute for Earth Science and Disaster Resilience","creatorNameLang":"en"}],"familyNames":[{"familyName":"防災科学技術研究所","familyNameLang":"ja"},{"familyName":"ボウサイカガクギジュツケンキュウショ","familyNameLang":"ja-Kana"},{"familyName":"National Research Institute for Earth Science and Disaster Resilience","familyNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1632","nameIdentifierScheme":"WEKO"},{"nameIdentifier":"DA04781797","nameIdentifierScheme":"CiNii","nameIdentifierURI":"https://ci.nii.ac.jp/author/DA04781797"}]}]},"item_1617186626617":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"防災科研では、国のイノベーションミッションを背景に「地震フリー空間」を実現するため、高機能な3次元免震装置の開発を進めています。本実験研究では、令和2年度(2020)の研究(E201902)で開発した試験体を基に、小型の2階建てビルを想定し、防災科研が保有するテストベッド(鉄骨構造試験体:7.0×5.5×H4.7m、60t)を水浮揚方式で水平免震しました。ただし、これと組み合わせる油圧パラレルリンク式鉛直免震装置は、試運転時の操作ミスにより破損したため、本加振実験時には取り外されています。1995年兵庫県南部地震(JR鷹取)などの地震波形を用いて加振実験を行った結果、過去に発生した強い揺れを伴う地震において、水平加速度をおおむね1/10以下に低減し、目標値を達成しました。迫力ある画像もぜひご覧ください。この実験で得られた計測データや画像は公開されています。","subitem_description_language":"ja","subitem_description_type":"Abstract"},{"subitem_description":"\"\"\"In response to the national innovation mission, NIED is exploring the development of high-performance seismic isolation devices to realize \"\"\"\"earthquake-free spaces.\"\"\"\" In this experimental study, based on the prototype developed in the 2020 research project (E201902), a test bed owned by NIED (steel frame structure prototype: 7.0 × 5.5 × H 4.7 m, 60 tons) was horizontally isolated using a water-levitation method, simulating a small two-story building. However, the hydraulic parallel-link vertical seismic isolation device, which was intended to be used in combination with the system, was removed from the experiment due to damage caused by operator error during a trial run. Shaking tests were conducted using seismic waveforms such as the 1995 Hyogoken-Nanbu Earthquake (JR Takatori record). As a result, the system successfully reduced horizontal accelerations to less than one-tenth of their original values during strong ground motions, achieving the target performance. Please take a look at the impressive images from the experiment.  The measurement data and images obtained from this experiment are available.\"\"\"","subitem_description_language":"en","subitem_description_type":"Abstract"},{"subitem_description":"データ取得:2021年 ","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"Data acquisition period : 2021","subitem_description_language":"en","subitem_description_type":"Other"},{"subitem_description":"お問い合わせ:asebi@bosai.go.jp ","subitem_description_language":"ja","subitem_description_type":"Other"},{"subitem_description":"inquiry: asebi@bosai.go.jp","subitem_description_language":"en","subitem_description_type":"Other"}]},"item_1617186643794":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_1522300295150":"ja","subitem_1522300316516":"防災科学技術研究所"},{"subitem_1522300295150":"en","subitem_1522300316516":"National Research Institute for Earth Science and Disaster Resilience"}]},"item_1617186660861":{"attribute_name":"Date","attribute_value_mlt":[{"subitem_1522300695726":"Issued","subitem_1522300722591":"2023"}]},"item_1617186783814":{"attribute_name":"識別子","attribute_value_mlt":[{"subitem_identifier_type":"DOI","subitem_identifier_uri":"10.17598/NIED.0020-E202006"}]},"item_1617258105262":{"attribute_name":"Resource Type","attribute_value_mlt":[{"resourcetype":"dataset","resourceuri":"http://purl.org/coar/resource_type/c_ddb1"}]},"item_1617353299429":{"attribute_name":"関連情報","attribute_value_mlt":[{"subitem_1522306207484":"isIdenticalTo","subitem_1522306287251":{"subitem_1522306382014":"URI","subitem_1522306436033":"https://asebi.bosai.go.jp/"},"subitem_1523320863692":[{"subitem_1523320867455":"en","subitem_1523320909613":"LOGIN Page for Registered Users"}]}]},"item_title":"60tテストベッドによる浮揚式3次元免震装置の加振実験","item_type_id":"40006","owner":"7","path":["1749778844647"],"publish_date":"2025-06-19","publish_status":"0","recid":"7233","relation_version_is_last":true,"title":["60tテストベッドによる浮揚式3次元免震装置の加振実験"],"weko_creator_id":"7","weko_shared_id":-1},"updated":"2025-06-23T05:38:43.877658+00:00"}