{"_buckets": {"deposit": "28017751-c20c-4a7d-97bb-96dba08d84eb"}, "_deposit": {"id": "2915", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2915"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00002915", "sets": []}, "author_link": [], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2001", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "10", "bibliographicPageEnd": "1710", "bibliographicPageStart": "1707", "bibliographicVolumeNumber": "126", "bibliographic_titles": [{"bibliographic_title": "Analyst", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Chemical and mass spectrometric procedures for thorium isotopic analysis using a highly sensitive multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with a retardation lens were developed. They were applied to thorium isotopic measurements in volcanic rock samples. Rock samples were digested in screw-capped Savillex beakers with HF-HClO4. Thorium was then isolated from the rock matrix by a conventional anion-exchange procedure. Purified thorium was analyzed using an MC-ICP-MS (Micromass, IsoProbe) with a micro-concentric nebulizer (Cetac Aridus). The sensitivity for thorium was about 80 V ppm-1, which enabled us to obtain a strong enough ion current to measure 230Th/232Th ratios with a 10 ppb solution. With these procedures, we were able to reduce the amount of thorium required for precise isotopic analysis to \u003c 10 ng. Mass-fractionation correction and Daly/Faraday multiplier gain calibration were applied using natural uranium standard solution. The procedures were applied to standard rock samples whose thorium isotopic ratios had been reported using thermal ionization mass spectrometry (TIMS). Thorium isotopic compositions measured for JB-1 and AGV-1 gave coincident values with the TIMS values. In addition, the 230Th/232Th radioactivity ratios of the three standard rocks including JR-2, with eruption ages of older than 350 kyr, were in equilibrium with those of 238U/232Th, confirming the accuracy of our analysis.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1039/b101593l"}}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0003-2654", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "S. Nakai", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "S. Fukuda", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "S. Nakada", "creatorNameLang": "en"}]}]}, "item_title": "Thorium isotopic measurements on silicate rock samples with a multi-collector inductively coupled plasma mass spectrometer", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Thorium isotopic measurements on silicate rock samples with a multi-collector inductively coupled plasma mass spectrometer", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1670839190650"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/2915", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-03-30"}, "publish_date": "2023-03-30", "publish_status": "0", "recid": "2915", "relation": {}, "relation_version_is_last": true, "title": ["Thorium isotopic measurements on silicate rock samples with a multi-collector inductively coupled plasma mass spectrometer"], "weko_shared_id": -1}
  1. 防災科研関係論文

Thorium isotopic measurements on silicate rock samples with a multi-collector inductively coupled plasma mass spectrometer

https://nied-repo.bosai.go.jp/records/2915
https://nied-repo.bosai.go.jp/records/2915
2ef7ce3d-fc08-4b1a-8f1b-3186fccd2b3d
Item type researchmap(1)
公開日 2023-03-30
タイトル
言語 en
タイトル Thorium isotopic measurements on silicate rock samples with a multi-collector inductively coupled plasma mass spectrometer
著者 S. Nakai

× S. Nakai

en S. Nakai

Search repository
S. Fukuda

× S. Fukuda

en S. Fukuda

Search repository
S. Nakada

× S. Nakada

en S. Nakada

Search repository
抄録
内容記述タイプ Other
内容記述 Chemical and mass spectrometric procedures for thorium isotopic analysis using a highly sensitive multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with a retardation lens were developed. They were applied to thorium isotopic measurements in volcanic rock samples. Rock samples were digested in screw-capped Savillex beakers with HF-HClO4. Thorium was then isolated from the rock matrix by a conventional anion-exchange procedure. Purified thorium was analyzed using an MC-ICP-MS (Micromass, IsoProbe) with a micro-concentric nebulizer (Cetac Aridus). The sensitivity for thorium was about 80 V ppm-1, which enabled us to obtain a strong enough ion current to measure 230Th/232Th ratios with a 10 ppb solution. With these procedures, we were able to reduce the amount of thorium required for precise isotopic analysis to < 10 ng. Mass-fractionation correction and Daly/Faraday multiplier gain calibration were applied using natural uranium standard solution. The procedures were applied to standard rock samples whose thorium isotopic ratios had been reported using thermal ionization mass spectrometry (TIMS). Thorium isotopic compositions measured for JB-1 and AGV-1 gave coincident values with the TIMS values. In addition, the 230Th/232Th radioactivity ratios of the three standard rocks including JR-2, with eruption ages of older than 350 kyr, were in equilibrium with those of 238U/232Th, confirming the accuracy of our analysis.
言語 en
書誌情報 en : Analyst

巻 126, 号 10, p. 1707-1710, 発行日 2001
ISSN
収録物識別子タイプ ISSN
収録物識別子 0003-2654
DOI
関連識別子 10.1039/b101593l
戻る
0
views
See details
Views

Versions

Ver.1 2023-03-30 09:21:05.451866
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings