{"_buckets": {"deposit": "f081924d-f85b-4ae4-9fda-adcfa0f812d8"}, "_deposit": {"id": "2952", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "2952"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00002952", "sets": []}, "author_link": [], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2013", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "36", "bibliographicPageStart": "33", "bibliographic_titles": [{"bibliographic_title": "Joint Urban Remote Sensing Event 2013, JURSE 2013", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Due to the remarkable improvements that have been made in radar sensors, high-resolution SAR images are now available, thus providing detailed ground surface information. In this study, a new method is developed to detect building heights automatically using 2D GIS data and a single high-resolution TerraSAR-X (TSX) intensity image. A building in a SAR image shows a layover from the actual position in the direction of the sensor, due to the side-looking nature of SAR. Since the length of the layover is proportional to the height of the building, it can be used to estimate the building height. To do this, we shift the building shape obtained from 2D GIS data in the direction of the sensor. The proposed method was tested on a TSX image of San Francisco, U.S.A. in HighSpot mode, using a resolution of about 1 m. Comparing the result with that obtained using Lidar data, the RMS error was found to be less than 3 m, which is about the height of one building story. c 2013 IEEE.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/JURSE.2013.6550659"}}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Wen Liu", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Fumio Yamazaki", "creatorNameLang": "en"}]}]}, "item_title": "Building height detection from high-resolution TerraSAR-X imagery and GIS data", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Building height detection from high-resolution TerraSAR-X imagery and GIS data", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1670839190650"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/2952", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-03-30"}, "publish_date": "2023-03-30", "publish_status": "0", "recid": "2952", "relation": {}, "relation_version_is_last": true, "title": ["Building height detection from high-resolution TerraSAR-X imagery and GIS data"], "weko_shared_id": -1}
  1. 防災科研関係論文

Building height detection from high-resolution TerraSAR-X imagery and GIS data

https://nied-repo.bosai.go.jp/records/2952
https://nied-repo.bosai.go.jp/records/2952
da3f43b7-9896-4ca0-b34c-3c5c40dd3061
Item type researchmap(1)
公開日 2023-03-30
タイトル
言語 en
タイトル Building height detection from high-resolution TerraSAR-X imagery and GIS data
著者 Wen Liu

× Wen Liu

en Wen Liu

Search repository
Fumio Yamazaki

× Fumio Yamazaki

en Fumio Yamazaki

Search repository
抄録
内容記述タイプ Other
内容記述 Due to the remarkable improvements that have been made in radar sensors, high-resolution SAR images are now available, thus providing detailed ground surface information. In this study, a new method is developed to detect building heights automatically using 2D GIS data and a single high-resolution TerraSAR-X (TSX) intensity image. A building in a SAR image shows a layover from the actual position in the direction of the sensor, due to the side-looking nature of SAR. Since the length of the layover is proportional to the height of the building, it can be used to estimate the building height. To do this, we shift the building shape obtained from 2D GIS data in the direction of the sensor. The proposed method was tested on a TSX image of San Francisco, U.S.A. in HighSpot mode, using a resolution of about 1 m. Comparing the result with that obtained using Lidar data, the RMS error was found to be less than 3 m, which is about the height of one building story. c 2013 IEEE.
言語 en
書誌情報 en : Joint Urban Remote Sensing Event 2013, JURSE 2013

p. 33-36, 発行日 2013
DOI
関連識別子 10.1109/JURSE.2013.6550659
戻る
0
views
See details
Views

Versions

Ver.1 2023-03-30 09:21:55.898019
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings