{"_buckets": {"deposit": "a3e15e6b-a54b-41ff-951d-04c0a89c0811"}, "_deposit": {"id": "3171", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "3171"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00003171", "sets": []}, "author_link": [], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2009", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "0", "bibliographicPageEnd": "327", "bibliographicPageStart": "322", "bibliographicVolumeNumber": "2009", "bibliographic_titles": [{"bibliographic_title": "「運動と振動の制御」シンポジウム講演論文集", "bibliographic_titleLang": "ja"}, {"bibliographic_title": "The Proceedings of the Symposium on the Motion and Vibration Control", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Tri-axial shake table tests on the piping system with wall thinning were conducted to obtain the effect of wall thinning on vibration characteristics and failure modes of piping system. The excitation test reached the fatigue failure of the elbow applied in the piping system but the failure could not cause under the excitation level beyond the limit of the piping design criteria. The test results suggest that the seismic design criterion for piping system has too much margin.", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "Tri-axial shake table tests on the piping system with wall thinning were conducted to obtain the effect of wall thinning on vibration characteristics and failure modes of piping system. The excitation test reached the fatigue failure of the elbow applied in the piping system but the failure could not cause under the excitation level beyond the limit of the piping design criteria. The test results suggest that the seismic design criterion for piping system has too much margin.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "一般社団法人 日本機械学会", "subitem_publisher_language": "ja"}, {"subitem_publisher": "The Japan Society of Mechanical Engineers", "subitem_publisher_language": "en"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1299/jsmemovic.2009.11.322"}}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "大谷 章仁", "creatorNameLang": "ja"}, {"creatorName": "OTANI Akihito", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "佐藤 祐二", "creatorNameLang": "ja"}, {"creatorName": "SATO Yuji", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "中村 いずみ", "creatorNameLang": "ja"}, {"creatorName": "NAKAMURA Izumi", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "高橋 宏治", "creatorNameLang": "ja"}, {"creatorName": "TAKAHASHI Koji", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "高田 一", "creatorNameLang": "ja"}, {"creatorName": "TAKADA Hajime", "creatorNameLang": "en"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_title": "C15 減肉配管の3次元加振実験と耐震設計裕度に関する考察(OS8 機械・機械構造物の耐震・免震・振動制御(2)2)", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "C15 減肉配管の3次元加振実験と耐震設計裕度に関する考察(OS8 機械・機械構造物の耐震・免震・振動制御(2)2)", "subitem_title_language": "ja"}, {"subitem_title": "C15 Thinned wall piping 3-D shaking table test and a consideration on seismic margin", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1670839190650"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/3171", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-03-30"}, "publish_date": "2023-03-30", "publish_status": "0", "recid": "3171", "relation": {}, "relation_version_is_last": true, "title": ["C15 減肉配管の3次元加振実験と耐震設計裕度に関する考察(OS8 機械・機械構造物の耐震・免震・振動制御(2)2)"], "weko_shared_id": -1}
C15 減肉配管の3次元加振実験と耐震設計裕度に関する考察(OS8 機械・機械構造物の耐震・免震・振動制御(2)2)
https://nied-repo.bosai.go.jp/records/3171
https://nied-repo.bosai.go.jp/records/3171