ログイン サインアップ
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

{"_buckets": {"deposit": "81613da3-383e-470c-ad3c-3e45950b8815"}, "_deposit": {"id": "4636", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "4636"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00004636", "sets": []}, "author_link": [], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "5", "bibliographicPageEnd": "562", "bibliographicPageStart": "560", "bibliographicVolumeNumber": "17", "bibliographic_titles": [{"bibliographic_title": "JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The direct analysis of mercury in sediment samples from Minamata Bay, Kumamoto, Japan was studied using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Two sediment and one soil certified reference material were analysed and used to construct the calibration curve. Direct analysis of sediment samples without internal standardization yielded satisfactory results. Elemental speciation and particle size within the studied range did not appear to significantly affect the measurements. With the LA-ICP-MS system, a sample throughput of 10 per h and a detection limit of 0.02 mg kg(-1) was achieved. Analytical results of 14 sediment samples using the present system were in good agreement with those obtained by isotope dilution cold vapour generation ICP-MS.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "ROYAL SOC CHEMISTRY", "subitem_publisher_language": "en"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1039/b202002p"}}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0267-9477", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "GH Tao", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Y Fujikawa", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "M Mitsui", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "R Yamada", "creatorNameLang": "en"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_title": "Determination of mercury in sediment samples by laser ablation inductively coupled plasma mass spectrometry", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Determination of mercury in sediment samples by laser ablation inductively coupled plasma mass spectrometry", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1670839190650"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/4636", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-03-30"}, "publish_date": "2023-03-30", "publish_status": "0", "recid": "4636", "relation": {}, "relation_version_is_last": true, "title": ["Determination of mercury in sediment samples by laser ablation inductively coupled plasma mass spectrometry"], "weko_shared_id": -1}
  1. 防災科研関係論文

Determination of mercury in sediment samples by laser ablation inductively coupled plasma mass spectrometry

https://nied-repo.bosai.go.jp/records/4636
https://nied-repo.bosai.go.jp/records/4636
559db106-709d-452b-8db1-d22c48db4cc3
Item type researchmap(1)
公開日 2023-03-30
タイトル
言語 en
タイトル Determination of mercury in sediment samples by laser ablation inductively coupled plasma mass spectrometry
言語
言語 eng
著者 GH Tao

× GH Tao

en GH Tao

Search repository
Y Fujikawa

× Y Fujikawa

en Y Fujikawa

Search repository
M Mitsui

× M Mitsui

en M Mitsui

Search repository
R Yamada

× R Yamada

en R Yamada

Search repository
抄録
内容記述タイプ Other
内容記述 The direct analysis of mercury in sediment samples from Minamata Bay, Kumamoto, Japan was studied using laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Two sediment and one soil certified reference material were analysed and used to construct the calibration curve. Direct analysis of sediment samples without internal standardization yielded satisfactory results. Elemental speciation and particle size within the studied range did not appear to significantly affect the measurements. With the LA-ICP-MS system, a sample throughput of 10 per h and a detection limit of 0.02 mg kg(-1) was achieved. Analytical results of 14 sediment samples using the present system were in good agreement with those obtained by isotope dilution cold vapour generation ICP-MS.
言語 en
書誌情報 en : JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY

巻 17, 号 5, p. 560-562, 発行日 2002
出版者
言語 en
出版者 ROYAL SOC CHEMISTRY
ISSN
収録物識別子タイプ ISSN
収録物識別子 0267-9477
DOI
関連識別子 10.1039/b202002p
戻る
0
views
See details
Views

Versions

Ver.1 2023-03-31 01:59:11.487811
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings