{"_buckets": {"deposit": "af839878-bf27-452b-a83e-41306ff33c92"}, "_deposit": {"id": "4782", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "4782"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00004782", "sets": []}, "author_link": [], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2004-02", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1", "bibliographicPageEnd": "90", "bibliographicPageStart": "85", "bibliographicVolumeNumber": "126", "bibliographic_titles": [{"bibliographic_title": "JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Shaking table tests of three-dimensional piping models with degradation were conducted in order to investigate the influence of degradation on dynamic behavior and failure modes of piping systems. The degradation condition induced in the piping models was about 50 percent full circumferential wall thinning at elbows. Four types of models were made for the shaking table tests by varying the location of wall thinning in the piping models. These models were excited under the same input acceleration until the models failed and a leak of pressurized internal water occurred. Through these tests, the change of the vibration characteristics and processes to failure of degraded piping models were obtained. The deformation of the piping models tended to concentrate on the degraded elbows, and the damage was concentrated on the weakest elbow in the piping models. The failure mode of the piping models was a low-cycle fatigue failure at the weakest elbow.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "ASME-AMER SOC MECHANICAL ENG", "subitem_publisher_language": "en"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1115/1.1638787"}}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0094-9930", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Nakamura, I", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "A Otani", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "M Shiratori", "creatorNameLang": "en"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_title": "Failure behavior of piping systems with wall thinning under seismic loading", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Failure behavior of piping systems with wall thinning under seismic loading", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "1", "path": ["1670839190650"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/4782", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2023-03-30"}, "publish_date": "2023-03-30", "publish_status": "0", "recid": "4782", "relation": {}, "relation_version_is_last": true, "title": ["Failure behavior of piping systems with wall thinning under seismic loading"], "weko_shared_id": -1}
Failure behavior of piping systems with wall thinning under seismic loading
https://nied-repo.bosai.go.jp/records/4782
https://nied-repo.bosai.go.jp/records/478256d74b1b-f57f-42ff-aff1-e85d600a447a
Item type | researchmap(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
公開日 | 2023-03-30 | |||||||||||
タイトル | ||||||||||||
言語 | en | |||||||||||
タイトル | Failure behavior of piping systems with wall thinning under seismic loading | |||||||||||
言語 | ||||||||||||
言語 | eng | |||||||||||
著者 |
Nakamura, I
× Nakamura, I
× A Otani
× M Shiratori
|
|||||||||||
抄録 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | Shaking table tests of three-dimensional piping models with degradation were conducted in order to investigate the influence of degradation on dynamic behavior and failure modes of piping systems. The degradation condition induced in the piping models was about 50 percent full circumferential wall thinning at elbows. Four types of models were made for the shaking table tests by varying the location of wall thinning in the piping models. These models were excited under the same input acceleration until the models failed and a leak of pressurized internal water occurred. Through these tests, the change of the vibration characteristics and processes to failure of degraded piping models were obtained. The deformation of the piping models tended to concentrate on the degraded elbows, and the damage was concentrated on the weakest elbow in the piping models. The failure mode of the piping models was a low-cycle fatigue failure at the weakest elbow. | |||||||||||
言語 | en | |||||||||||
書誌情報 |
en : JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME 巻 126, 号 1, p. 85-90, 発行日 2004-02 |
|||||||||||
出版者 | ||||||||||||
言語 | en | |||||||||||
出版者 | ASME-AMER SOC MECHANICAL ENG | |||||||||||
ISSN | ||||||||||||
収録物識別子タイプ | ISSN | |||||||||||
収録物識別子 | 0094-9930 | |||||||||||
DOI | ||||||||||||
関連識別子 | 10.1115/1.1638787 |