Alternative control design approach to shaking facilities for re-creating seismic motion
https://nied-repo.bosai.go.jp/records/4792
https://nied-repo.bosai.go.jp/records/4792ff6e9be9-6bdd-4836-8235-bbe535fe3057
| Item type | researchmap(1) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2023-03-30 | |||||||||||||||||
| タイトル | ||||||||||||||||||
| 言語 | en | |||||||||||||||||
| タイトル | Alternative control design approach to shaking facilities for re-creating seismic motion | |||||||||||||||||
| 言語 | ||||||||||||||||||
| 言語 | eng | |||||||||||||||||
| 著者 |
Eiji Sato
× Eiji Sato
× Tomoyoshi Kakegawa
× Taku Suzuki
× Koichi Kajiwara
× Yasutaka Tagawa
× Shigemitsu Takai
|
|||||||||||||||||
| 抄録 | ||||||||||||||||||
| 内容記述タイプ | Other | |||||||||||||||||
| 内容記述 | The 3-D Full-Scale Earthquake Testing Facility (E-Defense) is now under construction in Miki City near Kobe. When completed, the facility will have a 750-ton shaking table measuring 20 m by 15 m, with a maximum load mass of 1200 tons. It will be able to create vibration in three dimensions with six degrees of freedom. However, the test model considered for this facility has a mass of 1200 tons compared to the shaking table mass of 750 tons, i.e., 1.6 times as heavy as the shaking table and much larger than ordinary test models. In addition, the vibration characteristics change considerably during the experiment due to the damage done to the test weight. Therefore, a better control design is urgently needed in order to overcome these problems. This research suggests a control method that will reproduce the earthquake wave accurately on the shaking table and will consider the robustness. Moreover, we will verify its efficiency by performing a control experiment using an existing two- dimensional, three-degree-of-freedom small shaking table, to which this control method is applied. | |||||||||||||||||
| 言語 | en | |||||||||||||||||
| 書誌情報 |
en : American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP 巻 445, 号 1, p. 67-73, 発行日 2002 |
|||||||||||||||||
| ISSN | ||||||||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||||||||
| 収録物識別子 | 0277-027X | |||||||||||||||||
| DOI | ||||||||||||||||||
| 関連識別子 | 10.1115/PVP2002-1399 | |||||||||||||||||