WEKO3
アイテム
Controller evaluation technique using virtual test model in shaking table
https://nied-repo.bosai.go.jp/records/6768
https://nied-repo.bosai.go.jp/records/67689c4dccb1-3978-49ff-a8e4-b305765d52e4
| Item type | researchmap(1) | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 公開日 | 2024-09-09 | |||||||||||||
| タイトル | ||||||||||||||
| 言語 | en | |||||||||||||
| タイトル | Controller evaluation technique using virtual test model in shaking table | |||||||||||||
| 言語 | ||||||||||||||
| 言語 | eng | |||||||||||||
| 著者 |
Yasutaka Tagawa
× Yasutaka Tagawa
× Eiji Nagai
× Eiji Sato
× Kouichi Kajiwara
|
|||||||||||||
| 抄録 | ||||||||||||||
| 内容記述タイプ | Other | |||||||||||||
| 内容記述 | In control system design for shaking tables, it is well known that many times and kinds of experiments have to be done to find a suitable controller. However, the control experiments with the test model on the shaking table is sometimes very difficult to implement especially for large shaking table such as E-Defense, because it costs very much for constructing and installing the test model on the shaking table. If the test model dynamics can be taken into consideration without using real test model in the experiments, these experiments cost much less than the experiments with real test model. In this study, a controller evaluation technique is proposed using a virtual test model instead of using a real test model. By using the virtual test model, it is possible to evaluate control performance when the test model is equipped on the shaking table, without using the real test model. Copyright © 2005 by ASME. | |||||||||||||
| 言語 | en | |||||||||||||
| 書誌情報 |
en : American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP 巻 8, p. 95-100, 発行日 2005 |
|||||||||||||
| ISSN | ||||||||||||||
| 収録物識別子タイプ | ISSN | |||||||||||||
| 収録物識別子 | 0277-027X | |||||||||||||
| DOI | ||||||||||||||
| 関連識別子 | 10.1115/PVP2005-71465 | |||||||||||||