{"_buckets": {"deposit": "1efd8dec-1378-4ba0-8b45-1742748dcc01"}, "_deposit": {"created_by": 10, "id": "6995", "owners": [10], "pid": {"revision_id": 0, "type": "depid", "value": "6995"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00006995", "sets": []}, "author_link": [], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2019", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "766", "bibliographicPageEnd": "1543", "bibliographicPageStart": "1533", "bibliographicVolumeNumber": "84", "bibliographic_titles": [{"bibliographic_title": "日本建築学会構造系論文報告集", "bibliographic_titleLang": "ja"}, {"bibliographic_title": "Journal of Structural and Construction Engineering", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The objective of this study is to examine the effect of the base-isolated buildings during a collision with retaining wall using a shaking table and to evaluate by numerical simulation. First, the factors that influence the response of superstructure during a collision were identified from the experimental results. And, an appropriate process was proposed for the evaluation of story shear force. Second, time history analysis using impulse was proposed. This method could not only reproduce the response of superstructure during a collision, but also indicate the possibility to predict it without using collision analysis.", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Architectural Institute of Japan", "subitem_publisher_language": "en"}]}, "item_10001_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.3130/aijs.84.1533"}}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "1881-8153", "subitem_source_identifier_type": "EISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "福井弘久", "creatorNameLang": "ja"}, {"creatorName": "Hirohisa Fukui", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "藤谷秀雄", "creatorNameLang": "ja"}, {"creatorName": "Hideo Fujitani", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "向井洋一", "creatorNameLang": "ja"}, {"creatorName": "Yoichi Mukai", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "伊藤麻衣", "creatorNameLang": "ja"}, {"creatorName": "Mai Ito", "creatorNameLang": "en"}]}, {"creatorNames": [{"creatorName": "Gilberto Mosqueda", "creatorNameLang": "ja"}, {"creatorName": "Gilberto Mosqueda", "creatorNameLang": "en"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_title": "免震構造の擁壁衝突時の上部構造の応答評価と力積を用いた解析", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "免震構造の擁壁衝突時の上部構造の応答評価と力積を用いた解析", "subitem_title_language": "ja"}, {"subitem_title": "Response evaluation and analysis using impulse of base-isolated buildings during a collision with retaining wall", "subitem_title_language": "en"}]}, "item_type_id": "40001", "owner": "10", "path": ["1670839190650"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/6995", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2025-02-25"}, "publish_date": "2025-02-25", "publish_status": "0", "recid": "6995", "relation": {}, "relation_version_is_last": true, "title": ["免震構造の擁壁衝突時の上部構造の応答評価と力積を用いた解析"], "weko_shared_id": -1}
免震構造の擁壁衝突時の上部構造の応答評価と力積を用いた解析
https://nied-repo.bosai.go.jp/records/6995
https://nied-repo.bosai.go.jp/records/6995