{"_buckets": {"deposit": "ec414e61-abd3-4d6c-abed-c9d2a335f0fe"}, "_deposit": {"created_by": 7, "id": "7147", "owners": [7], "pid": {"revision_id": 0, "type": "depid", "value": "7147"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00007147", "sets": ["1749778844647"]}, "author_link": ["1632"], "control_number": "7147", "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "実大鉄筋コンクリート建物の三次元震動破壊実験", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Three-dimensional Seismic Structural Failure Experiment of Full-scale RC Buildings", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "作成者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "防災科学技術研究所", "creatorNameLang": "ja"}, {"creatorName": "ボウサイカガクギジュツケンキュウショ", "creatorNameLang": "ja-Kana"}, {"creatorName": "National Research Institute for Earth Science and Disaster Resilience", "creatorNameLang": "en"}], "familyNames": [{"familyName": "防災科学技術研究所", "familyNameLang": "ja"}, {"familyName": "ボウサイカガクギジュツケンキュウショ", "familyNameLang": "ja-Kana"}, {"familyName": "National Research Institute for Earth Science and Disaster Resilience", "familyNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1632", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "DA04781797", "nameIdentifierScheme": "CiNii", "nameIdentifierURI": "https://ci.nii.ac.jp/author/DA04781797"}]}]}, "item_1617186626617": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "文部科学省『大都市大震災軽減化特別プロジェクト』の一環として、1970年代当時の一般的な設計手法により設計した実大6層鉄筋コンクリート建物の震動台実験を実施しました。試験体は、縦 12 m、横17 m、高さ16 mの6層構造で、その重量はE-ディフェンス稼働以来の最大重量となる約1,000トンです。実験では、1995年兵庫県南部地震で実際に観測された震度6強の地震を3次元で再現し、建物の挙動を調べ鉄筋コンクリート建物の耐震性向上に必要なデータを取得しました。", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "As a part of “Special Project for Earthquake Disaster Mitigation in Urban Areas” supported by Ministry of Education, Culture, Sports, Science and Technology (MEXT), a shake table test was conducted on a full-scale six-story reinforced concrete building designed using the typical design methods of the 1970s. The test specimen was a 6-story structure measuring 12m long, 17 m wide and 16 m high, and weighed approximately 1,000 tons, the largest weight ever to be used in E-Defense. The experiment reproduced a 6-upper earthquake, which was actually observed in the 1995 Hyogo-ken Nanbu Earthquake, in three directions to examine the behavior of the building and obtain the data necessary to improve the seismic resistance of reinforced concrete buildings.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "データ取得:2006年", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "Data acquisition period : 2006", "subitem_description_language": "en", "subitem_description_type": "Other"}, {"subitem_description": "お問い合わせ:asebi@bosai.go.jp", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "inquiry: asebi@bosai.go.jp", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "防災科学技術研究所"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "National Research Institute for Earth Science and Disaster Resilience"}]}, "item_1617186660861": {"attribute_name": "Date", "attribute_value_mlt": [{"subitem_1522300695726": "Issued", "subitem_1522300722591": "2025-04-16"}]}, "item_1617186783814": {"attribute_name": "識別子", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "10.17598/NIED.0020-E200506"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "dataset", "resourceuri": "http://purl.org/coar/resource_type/c_ddb1"}]}, "item_1617353299429": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_1522306207484": "isIdenticalTo", "subitem_1522306287251": {"subitem_1522306382014": "URI", "subitem_1522306436033": "https://asebi.bosai.go.jp/"}, "subitem_1523320863692": [{"subitem_1523320867455": "en", "subitem_1523320909613": "LOGIN Page for Registered Users"}]}]}, "item_title": "実大鉄筋コンクリート建物の三次元震動破壊実験", "item_type_id": "40006", "owner": "7", "path": ["1749778844647"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/7147", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2025-06-19"}, "publish_date": "2025-06-19", "publish_status": "0", "recid": "7147", "relation": {}, "relation_version_is_last": true, "title": ["実大鉄筋コンクリート建物の三次元震動破壊実験"], "weko_shared_id": -1}
  1. 研究データ
  2. ASEBI

実大鉄筋コンクリート建物の三次元震動破壊実験

https://nied-repo.bosai.go.jp/records/7147

DOI

https://doi.org/10.17598/NIED.0020-E200506
https://nied-repo.bosai.go.jp/records/7147
90881dc2-1d59-424d-aef0-a65b71760b24
Item type データセット / Dataset(1)
タイトル
タイトル 実大鉄筋コンクリート建物の三次元震動破壊実験
言語 ja
タイトル
タイトル Three-dimensional Seismic Structural Failure Experiment of Full-scale RC Buildings
言語 en
作成者 防災科学技術研究所

× 防災科学技術研究所

WEKO 1632
CiNii DA04781797

ja 防災科学技術研究所

ja-Kana ボウサイカガクギジュツケンキュウショ

en National Research Institute for Earth Science and Disaster Resilience

Search repository
内容記述
内容記述タイプ Abstract
内容記述 文部科学省『大都市大震災軽減化特別プロジェクト』の一環として、1970年代当時の一般的な設計手法により設計した実大6層鉄筋コンクリート建物の震動台実験を実施しました。試験体は、縦 12 m、横17 m、高さ16 mの6層構造で、その重量はE-ディフェンス稼働以来の最大重量となる約1,000トンです。実験では、1995年兵庫県南部地震で実際に観測された震度6強の地震を3次元で再現し、建物の挙動を調べ鉄筋コンクリート建物の耐震性向上に必要なデータを取得しました。
言語 ja
内容記述
内容記述タイプ Abstract
内容記述 As a part of “Special Project for Earthquake Disaster Mitigation in Urban Areas” supported by Ministry of Education, Culture, Sports, Science and Technology (MEXT), a shake table test was conducted on a full-scale six-story reinforced concrete building designed using the typical design methods of the 1970s. The test specimen was a 6-story structure measuring 12m long, 17 m wide and 16 m high, and weighed approximately 1,000 tons, the largest weight ever to be used in E-Defense. The experiment reproduced a 6-upper earthquake, which was actually observed in the 1995 Hyogo-ken Nanbu Earthquake, in three directions to examine the behavior of the building and obtain the data necessary to improve the seismic resistance of reinforced concrete buildings.
言語 en
内容記述
内容記述タイプ Other
内容記述 データ取得:2006年
言語 ja
内容記述
内容記述タイプ Other
内容記述 Data acquisition period : 2006
言語 en
内容記述
内容記述タイプ Other
内容記述 お問い合わせ:asebi@bosai.go.jp
言語 ja
内容記述
内容記述タイプ Other
内容記述 inquiry: asebi@bosai.go.jp
言語 en
出版者
言語 ja
出版者 防災科学技術研究所
出版者
言語 en
出版者 National Research Institute for Earth Science and Disaster Resilience
日付
日付タイプ Issued
日付 2025-04-16
資源タイプ
資源タイプ dataset
資源タイプ識別子 http://purl.org/coar/resource_type/c_ddb1
識別子
識別子 10.17598/NIED.0020-E200506
識別子タイプ DOI
関連情報
関連タイプ isIdenticalTo
識別子タイプ URI
関連識別子 https://asebi.bosai.go.jp/
関連名称 LOGIN Page for Registered Users(en)
戻る
0
views
See details
Views

Versions

Ver.1 2025-06-13 01:57:56.009026
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings