{"_buckets": {"deposit": "e78f6cff-9249-4069-8ae8-e91880793121"}, "_deposit": {"created_by": 7, "id": "7160", "owners": [7], "pid": {"revision_id": 0, "type": "depid", "value": "7160"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00007160", "sets": ["1749778844647"]}, "author_link": ["1632"], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "鉄骨造建物実験研究 完全崩壊再現実験", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Experimental Study on Complete Collapse of Steel Frame Building", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "作成者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "防災科学技術研究所", "creatorNameLang": "ja"}, {"creatorName": "ボウサイカガクギジュツケンキュウショ", "creatorNameLang": "ja-Kana"}, {"creatorName": "National Research Institute for Earth Science and Disaster Resilience", "creatorNameLang": "en"}], "familyNames": [{"familyName": "防災科学技術研究所", "familyNameLang": "ja"}, {"familyName": "ボウサイカガクギジュツケンキュウショ", "familyNameLang": "ja-Kana"}, {"familyName": "National Research Institute for Earth Science and Disaster Resilience", "familyNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1632", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "DA04781797", "nameIdentifierScheme": "CiNii", "nameIdentifierURI": "https://ci.nii.ac.jp/author/DA04781797"}]}]}, "item_1617186626617": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "E-ディフェンスを用いた、実大4階建鉄骨造建物の震動台実験を実施しました。 試験体は、現行の建築基準法で定められる最低限の安全性を満足するよう設計され、鉄骨の構造骨組だけでなく、コンクリートの床・軽量コンクリートの外壁・アルミサッシ・ガラス窓・石膏ボードの間仕切壁・天井など、非構造体と呼ばれる部材も含めて、建物としての主要な要素を全て再現しています。 実験は、1995年兵庫県南部地震の観測地震動など、微小地震から震動台の最大能力を使った極大地震まで、徐々に加振レベルを上げて行いました。その結果、1層柱の柱頭・柱脚に著しい局部座屈が進展して耐力低下が顕著となり、1層部分が層崩壊しました。 ", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "A shake table test was conducted on a full-scale 4-story steel-framed building using the large-scale shaking table E-Defense. The test specimen was designed to satisfy the minimum level of performance required by the current building standards, and it reproduced all the main elements of a building, including not only the steel frame structure, but also non-structural elements such as the concrete floor, lightweight concrete exterior walls, aluminum sashes, glass windows, plasterboard partition walls, and ceiling. The experiments were conducted by gradually increasing the shaking level, from small earthquakes up to extremely large earthquakes using the maximum capacity of the shaking table, including the observed seismic motion of the 1995 Hyogo-ken Nanbu Earthquake. As a result, significant local buckling developed at the top and bottom of the columns in the first story, and the bearing capacity decreased significantly, causing collapse of the first story.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "データ取得:2007年 ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "Data acquisition period : 2007", "subitem_description_language": "en", "subitem_description_type": "Other"}, {"subitem_description": "お問い合わせ:asebi@bosai.go.jp ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "inquiry: asebi@bosai.go.jp", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "防災科学技術研究所"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "National Research Institute for Earth Science and Disaster Resilience"}]}, "item_1617186660861": {"attribute_name": "Date", "attribute_value_mlt": [{"subitem_1522300695726": "Issued", "subitem_1522300722591": "2009"}]}, "item_1617186783814": {"attribute_name": "識別子", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "10.17598/NIED.0020-E200703"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "dataset", "resourceuri": "http://purl.org/coar/resource_type/c_ddb1"}]}, "item_1617353299429": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_1522306207484": "isIdenticalTo", "subitem_1522306287251": {"subitem_1522306382014": "URI", "subitem_1522306436033": "https://asebi.bosai.go.jp/"}, "subitem_1523320863692": [{"subitem_1523320867455": "en", "subitem_1523320909613": "LOGIN Page for Registered Users"}]}]}, "item_title": "鉄骨造建物実験研究 完全崩壊再現実験", "item_type_id": "40006", "owner": "7", "path": ["1749778844647"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/7160", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2025-06-19"}, "publish_date": "2025-06-19", "publish_status": "0", "recid": "7160", "relation": {}, "relation_version_is_last": true, "title": ["鉄骨造建物実験研究 完全崩壊再現実験"], "weko_shared_id": -1}
  1. 研究データ
  2. ASEBI

鉄骨造建物実験研究 完全崩壊再現実験

https://nied-repo.bosai.go.jp/records/7160

DOI

https://doi.org/10.17598/NIED.0020-E200703
https://nied-repo.bosai.go.jp/records/7160
9f23b5c9-b8ed-4f20-b035-37468546092c
Item type データセット / Dataset(1)
タイトル
タイトル 鉄骨造建物実験研究 完全崩壊再現実験
言語 ja
タイトル
タイトル Experimental Study on Complete Collapse of Steel Frame Building
言語 en
作成者 防災科学技術研究所

× 防災科学技術研究所

WEKO 1632
CiNii DA04781797

ja 防災科学技術研究所

ja-Kana ボウサイカガクギジュツケンキュウショ

en National Research Institute for Earth Science and Disaster Resilience

Search repository
内容記述
内容記述タイプ Abstract
内容記述 E-ディフェンスを用いた、実大4階建鉄骨造建物の震動台実験を実施しました。 試験体は、現行の建築基準法で定められる最低限の安全性を満足するよう設計され、鉄骨の構造骨組だけでなく、コンクリートの床・軽量コンクリートの外壁・アルミサッシ・ガラス窓・石膏ボードの間仕切壁・天井など、非構造体と呼ばれる部材も含めて、建物としての主要な要素を全て再現しています。 実験は、1995年兵庫県南部地震の観測地震動など、微小地震から震動台の最大能力を使った極大地震まで、徐々に加振レベルを上げて行いました。その結果、1層柱の柱頭・柱脚に著しい局部座屈が進展して耐力低下が顕著となり、1層部分が層崩壊しました。
言語 ja
内容記述
内容記述タイプ Abstract
内容記述 A shake table test was conducted on a full-scale 4-story steel-framed building using the large-scale shaking table E-Defense. The test specimen was designed to satisfy the minimum level of performance required by the current building standards, and it reproduced all the main elements of a building, including not only the steel frame structure, but also non-structural elements such as the concrete floor, lightweight concrete exterior walls, aluminum sashes, glass windows, plasterboard partition walls, and ceiling. The experiments were conducted by gradually increasing the shaking level, from small earthquakes up to extremely large earthquakes using the maximum capacity of the shaking table, including the observed seismic motion of the 1995 Hyogo-ken Nanbu Earthquake. As a result, significant local buckling developed at the top and bottom of the columns in the first story, and the bearing capacity decreased significantly, causing collapse of the first story.
言語 en
内容記述
内容記述タイプ Other
内容記述 データ取得:2007年
言語 ja
内容記述
内容記述タイプ Other
内容記述 Data acquisition period : 2007
言語 en
内容記述
内容記述タイプ Other
内容記述 お問い合わせ:asebi@bosai.go.jp
言語 ja
内容記述
内容記述タイプ Other
内容記述 inquiry: asebi@bosai.go.jp
言語 en
出版者
言語 ja
出版者 防災科学技術研究所
出版者
言語 en
出版者 National Research Institute for Earth Science and Disaster Resilience
日付
日付タイプ Issued
日付 2009
資源タイプ
資源タイプ dataset
資源タイプ識別子 http://purl.org/coar/resource_type/c_ddb1
識別子
識別子 10.17598/NIED.0020-E200703
識別子タイプ DOI
関連情報
関連タイプ isIdenticalTo
識別子タイプ URI
関連識別子 https://asebi.bosai.go.jp/
関連名称 LOGIN Page for Registered Users(en)
戻る
0
views
See details
Views

Versions

Ver.1 2025-06-13 01:58:31.542992
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings