{"_buckets": {"deposit": "fca4c8d6-f703-4ebf-b876-28e95b27394d"}, "_deposit": {"created_by": 7, "id": "7164", "owners": [7], "pid": {"revision_id": 0, "type": "depid", "value": "7164"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00007164", "sets": ["1749778844647"]}, "author_link": ["1632"], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "設計地震動を超える入力に対する水平免震プラントの応答特性に関する研究", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Study on the Response Characteristics of Horizontal Seismically Isolated Plants to Inputs Exceeding Design Motions", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "作成者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "防災科学技術研究所", "creatorNameLang": "ja"}, {"creatorName": "ボウサイカガクギジュツケンキュウショ", "creatorNameLang": "ja-Kana"}, {"creatorName": "National Research Institute for Earth Science and Disaster Resilience", "creatorNameLang": "en"}], "familyNames": [{"familyName": "防災科学技術研究所", "familyNameLang": "ja"}, {"familyName": "ボウサイカガクギジュツケンキュウショ", "familyNameLang": "ja-Kana"}, {"familyName": "National Research Institute for Earth Science and Disaster Resilience", "familyNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1632", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "DA04781797", "nameIdentifierScheme": "CiNii", "nameIdentifierURI": "https://ci.nii.ac.jp/author/DA04781797"}]}]}, "item_1617186626617": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "【財団法人電力中央研究所による施設貸与実験】設計地震動レベルおよび設計地震動を超える地震動に対して、免震システムの地震時挙動を把握するため、E-ディフェンスを用いて、実機により近いスケールでの水平免震システムの振動台実験を実施しました。上部基礎版部と壁構造部から成る上部建屋試験体と、鉛プラグ入り積層ゴム(LRB)を含む免震層から構成されている試験体を作製して、暫定設計地震動や過去の地震における観測地震動を入力しました。実験の結果、設計地震動レベルの加振では、いずれも水平方向に関して加速度応答が低減しましたが、上下応答に関しては応答増幅すること等が確認されています。", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "【Facility Rental Experiment Conducted by Central Research Institute of Electric Power Industry】To understand the seismic behavior of the isolation system in ground motions exceeding the design seismic motion level and design motions, shake table tests of a horizontally isolated system were conducted using E-Defense at a scale closer to that of the actual structure. A test specimen consisting of an upper building model composed of an upper foundation plate and wall structure, and an isolation layer containing Lead Rubber Bearings (LRB), was constructed. Temporary design seismic motions and observed seismic motions from past earthquakes were input into the test specimen. The experimental results showed that, under design seismic motion levels, the horizontal acceleration response was reduced, while the vertical response exhibited amplification, among other phenomena.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "データ取得:2008年 ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "Data acquisition period : 2008", "subitem_description_language": "en", "subitem_description_type": "Other"}, {"subitem_description": "お問い合わせ:asebi@bosai.go.jp ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "inquiry: asebi@bosai.go.jp", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "防災科学技術研究所"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "National Research Institute for Earth Science and Disaster Resilience"}]}, "item_1617186660861": {"attribute_name": "Date", "attribute_value_mlt": [{"subitem_1522300695726": "Issued", "subitem_1522300722591": "2010"}]}, "item_1617186783814": {"attribute_name": "識別子", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "10.17598/NIED.0020-E200708"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "dataset", "resourceuri": "http://purl.org/coar/resource_type/c_ddb1"}]}, "item_1617353299429": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_1522306207484": "isIdenticalTo", "subitem_1522306287251": {"subitem_1522306382014": "URI", "subitem_1522306436033": "https://asebi.bosai.go.jp/"}, "subitem_1523320863692": [{"subitem_1523320867455": "en", "subitem_1523320909613": "LOGIN Page for Registered Users"}]}]}, "item_title": "設計地震動を超える入力に対する水平免震プラントの応答特性に関する研究", "item_type_id": "40006", "owner": "7", "path": ["1749778844647"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/7164", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2025-06-19"}, "publish_date": "2025-06-19", "publish_status": "0", "recid": "7164", "relation": {}, "relation_version_is_last": true, "title": ["設計地震動を超える入力に対する水平免震プラントの応答特性に関する研究"], "weko_shared_id": -1}
  1. 研究データ
  2. ASEBI

設計地震動を超える入力に対する水平免震プラントの応答特性に関する研究

https://nied-repo.bosai.go.jp/records/7164

DOI

https://doi.org/10.17598/NIED.0020-E200708
https://nied-repo.bosai.go.jp/records/7164
5d997dc9-62ac-45d3-82ac-5a9ec0370888
Item type データセット / Dataset(1)
タイトル
タイトル 設計地震動を超える入力に対する水平免震プラントの応答特性に関する研究
言語 ja
タイトル
タイトル Study on the Response Characteristics of Horizontal Seismically Isolated Plants to Inputs Exceeding Design Motions
言語 en
作成者 防災科学技術研究所

× 防災科学技術研究所

WEKO 1632
CiNii DA04781797

ja 防災科学技術研究所

ja-Kana ボウサイカガクギジュツケンキュウショ

en National Research Institute for Earth Science and Disaster Resilience

Search repository
内容記述
内容記述タイプ Abstract
内容記述 【財団法人電力中央研究所による施設貸与実験】設計地震動レベルおよび設計地震動を超える地震動に対して、免震システムの地震時挙動を把握するため、E-ディフェンスを用いて、実機により近いスケールでの水平免震システムの振動台実験を実施しました。上部基礎版部と壁構造部から成る上部建屋試験体と、鉛プラグ入り積層ゴム(LRB)を含む免震層から構成されている試験体を作製して、暫定設計地震動や過去の地震における観測地震動を入力しました。実験の結果、設計地震動レベルの加振では、いずれも水平方向に関して加速度応答が低減しましたが、上下応答に関しては応答増幅すること等が確認されています。
言語 ja
内容記述
内容記述タイプ Abstract
内容記述 【Facility Rental Experiment Conducted by Central Research Institute of Electric Power Industry】To understand the seismic behavior of the isolation system in ground motions exceeding the design seismic motion level and design motions, shake table tests of a horizontally isolated system were conducted using E-Defense at a scale closer to that of the actual structure. A test specimen consisting of an upper building model composed of an upper foundation plate and wall structure, and an isolation layer containing Lead Rubber Bearings (LRB), was constructed. Temporary design seismic motions and observed seismic motions from past earthquakes were input into the test specimen. The experimental results showed that, under design seismic motion levels, the horizontal acceleration response was reduced, while the vertical response exhibited amplification, among other phenomena.
言語 en
内容記述
内容記述タイプ Other
内容記述 データ取得:2008年
言語 ja
内容記述
内容記述タイプ Other
内容記述 Data acquisition period : 2008
言語 en
内容記述
内容記述タイプ Other
内容記述 お問い合わせ:asebi@bosai.go.jp
言語 ja
内容記述
内容記述タイプ Other
内容記述 inquiry: asebi@bosai.go.jp
言語 en
出版者
言語 ja
出版者 防災科学技術研究所
出版者
言語 en
出版者 National Research Institute for Earth Science and Disaster Resilience
日付
日付タイプ Issued
日付 2010
資源タイプ
資源タイプ dataset
資源タイプ識別子 http://purl.org/coar/resource_type/c_ddb1
識別子
識別子 10.17598/NIED.0020-E200708
識別子タイプ DOI
関連情報
関連タイプ isIdenticalTo
識別子タイプ URI
関連識別子 https://asebi.bosai.go.jp/
関連名称 LOGIN Page for Registered Users(en)
戻る
0
views
See details
Views

Versions

Ver.1 2025-06-13 01:58:22.879649
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings