{"_buckets": {"deposit": "77882a11-88d5-4c88-a3ed-00726ae523e9"}, "_deposit": {"created_by": 7, "id": "7218", "owners": [7], "pid": {"revision_id": 0, "type": "depid", "value": "7218"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00007218", "sets": ["1749778844647"]}, "author_link": ["1632"], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "耐震等級の異なる木造住宅の耐震性能検証に関する実験", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Experiments on Verification of Seismic Performance of Wooden Houses with Different Seismic Grades", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "作成者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "防災科学技術研究所", "creatorNameLang": "ja"}, {"creatorName": "ボウサイカガクギジュツケンキュウショ", "creatorNameLang": "ja-Kana"}, {"creatorName": "National Research Institute for Earth Science and Disaster Resilience", "creatorNameLang": "en"}], "familyNames": [{"familyName": "防災科学技術研究所", "familyNameLang": "ja"}, {"familyName": "ボウサイカガクギジュツケンキュウショ", "familyNameLang": "ja-Kana"}, {"familyName": "National Research Institute for Earth Science and Disaster Resilience", "familyNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1632", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "DA04781797", "nameIdentifierScheme": "CiNii", "nameIdentifierURI": "https://ci.nii.ac.jp/author/DA04781797"}]}]}, "item_1617186626617": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "【タマホーム株式会社による施設貸与実験】耐震性能の異なる 3 棟の建物(耐震等級 3の標準的な販売住宅と、耐震等級 5 相当の高耐震住宅、そして耐震等級 1の建築基準法が定める住宅)を製作して、1995年兵庫県南部地震や2016 年熊本地震レベルの強振動を複数回加えて、その性能の差異を比較しました。実験により得られたデータを基に解析・検証をより精度よく実施して、今後の住宅販売や耐震設計に活用しています。また、専門的な知識がなくても直感的にも理解・イメージし易い映像データを収集することで、耐震性能の重要性を改めて訴求しました。", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "【Facility Rental Experiment Conducted by Tama Home Co., Ltd】Three buildings with different seismic performance (a standard sales house with an seismic grade of 3, a high seismic resistance house equivalent to seismic grade 5, and a house with a seismic grade 1 as defined by the Building Standard Law) were constructed and subjected to multiple strong earthquake excitations recorded at the 1995 Hyogo-ken Nanbu Earthquake and 2016 Kumamoto Earthquake levels to compare their different seismic performance. Based on the data obtained from the experiments, analysis and verification have been conducted with greater precision and are utilized for future home sales and seismic design. In addition, by collecting visual data that is easy to understand and visualize even intuitively without specialized knowledge, it was possible to reemphasize the importance of the seismic performance of the houses.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "データ取得:2017年 ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "Data acquisition period : 2017", "subitem_description_language": "en", "subitem_description_type": "Other"}, {"subitem_description": "お問い合わせ:asebi@bosai.go.jp ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "inquiry: asebi@bosai.go.jp", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "防災科学技術研究所"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "National Research Institute for Earth Science and Disaster Resilience"}]}, "item_1617186660861": {"attribute_name": "Date", "attribute_value_mlt": [{"subitem_1522300695726": "Issued", "subitem_1522300722591": "2019"}]}, "item_1617186783814": {"attribute_name": "識別子", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "10.17598/NIED.0020-E201703"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "dataset", "resourceuri": "http://purl.org/coar/resource_type/c_ddb1"}]}, "item_1617353299429": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_1522306207484": "isIdenticalTo", "subitem_1522306287251": {"subitem_1522306382014": "URI", "subitem_1522306436033": "https://asebi.bosai.go.jp/"}, "subitem_1523320863692": [{"subitem_1523320867455": "en", "subitem_1523320909613": "LOGIN Page for Registered Users"}]}]}, "item_title": "耐震等級の異なる木造住宅の耐震性能検証に関する実験", "item_type_id": "40006", "owner": "7", "path": ["1749778844647"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/7218", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2025-06-19"}, "publish_date": "2025-06-19", "publish_status": "0", "recid": "7218", "relation": {}, "relation_version_is_last": true, "title": ["耐震等級の異なる木造住宅の耐震性能検証に関する実験"], "weko_shared_id": -1}
耐震等級の異なる木造住宅の耐震性能検証に関する実験
https://nied-repo.bosai.go.jp/records/7218
DOI
91dd1320-b28f-4a88-b176-08d289dfe2f1
Item type | データセット / Dataset(1) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
タイトル | ||||||||||||
タイトル | 耐震等級の異なる木造住宅の耐震性能検証に関する実験 | |||||||||||
言語 | ja | |||||||||||
タイトル | ||||||||||||
タイトル | Experiments on Verification of Seismic Performance of Wooden Houses with Different Seismic Grades | |||||||||||
言語 | en | |||||||||||
作成者 |
防災科学技術研究所
× 防災科学技術研究所
WEKO
1632
|
|||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | 【タマホーム株式会社による施設貸与実験】耐震性能の異なる 3 棟の建物(耐震等級 3の標準的な販売住宅と、耐震等級 5 相当の高耐震住宅、そして耐震等級 1の建築基準法が定める住宅)を製作して、1995年兵庫県南部地震や2016 年熊本地震レベルの強振動を複数回加えて、その性能の差異を比較しました。実験により得られたデータを基に解析・検証をより精度よく実施して、今後の住宅販売や耐震設計に活用しています。また、専門的な知識がなくても直感的にも理解・イメージし易い映像データを収集することで、耐震性能の重要性を改めて訴求しました。 | |||||||||||
言語 | ja | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Abstract | |||||||||||
内容記述 | 【Facility Rental Experiment Conducted by Tama Home Co., Ltd】Three buildings with different seismic performance (a standard sales house with an seismic grade of 3, a high seismic resistance house equivalent to seismic grade 5, and a house with a seismic grade 1 as defined by the Building Standard Law) were constructed and subjected to multiple strong earthquake excitations recorded at the 1995 Hyogo-ken Nanbu Earthquake and 2016 Kumamoto Earthquake levels to compare their different seismic performance. Based on the data obtained from the experiments, analysis and verification have been conducted with greater precision and are utilized for future home sales and seismic design. In addition, by collecting visual data that is easy to understand and visualize even intuitively without specialized knowledge, it was possible to reemphasize the importance of the seismic performance of the houses. | |||||||||||
言語 | en | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | データ取得:2017年 | |||||||||||
言語 | ja | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | Data acquisition period : 2017 | |||||||||||
言語 | en | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | お問い合わせ:asebi@bosai.go.jp | |||||||||||
言語 | ja | |||||||||||
内容記述 | ||||||||||||
内容記述タイプ | Other | |||||||||||
内容記述 | inquiry: asebi@bosai.go.jp | |||||||||||
言語 | en | |||||||||||
出版者 | ||||||||||||
言語 | ja | |||||||||||
出版者 | 防災科学技術研究所 | |||||||||||
出版者 | ||||||||||||
言語 | en | |||||||||||
出版者 | National Research Institute for Earth Science and Disaster Resilience | |||||||||||
日付 | ||||||||||||
日付タイプ | Issued | |||||||||||
日付 | 2019 | |||||||||||
資源タイプ | ||||||||||||
資源タイプ | dataset | |||||||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_ddb1 | |||||||||||
識別子 | ||||||||||||
識別子 | 10.17598/NIED.0020-E201703 | |||||||||||
識別子タイプ | DOI | |||||||||||
関連情報 | ||||||||||||
関連タイプ | isIdenticalTo | |||||||||||
識別子タイプ | URI | |||||||||||
関連識別子 | https://asebi.bosai.go.jp/ | |||||||||||
関連名称 | LOGIN Page for Registered Users(en) |