{"_buckets": {"deposit": "db1cecdd-bcb7-4af3-bf0b-32245323cf45"}, "_deposit": {"created_by": 7, "id": "7208", "owners": [7], "pid": {"revision_id": 0, "type": "depid", "value": "7208"}, "status": "published"}, "_oai": {"id": "oai:nied-repo.bosai.go.jp:00007208", "sets": ["1749778844647"]}, "author_link": ["1632"], "item_1617186331708": {"attribute_name": "Title", "attribute_value_mlt": [{"subitem_1551255647225": "CLTパネルを用いた建築物の構造性能検証震動台実験", "subitem_1551255648112": "ja"}, {"subitem_1551255647225": "Shaking Table Testing to verify the Seismic Performance of CLT Buildings", "subitem_1551255648112": "en"}]}, "item_1617186419668": {"attribute_name": "作成者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "防災科学技術研究所", "creatorNameLang": "ja"}, {"creatorName": "ボウサイカガクギジュツケンキュウショ", "creatorNameLang": "ja-Kana"}, {"creatorName": "National Research Institute for Earth Science and Disaster Resilience", "creatorNameLang": "en"}], "familyNames": [{"familyName": "防災科学技術研究所", "familyNameLang": "ja"}, {"familyName": "ボウサイカガクギジュツケンキュウショ", "familyNameLang": "ja-Kana"}, {"familyName": "National Research Institute for Earth Science and Disaster Resilience", "familyNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1632", "nameIdentifierScheme": "WEKO"}, {"nameIdentifier": "DA04781797", "nameIdentifierScheme": "CiNii", "nameIdentifierURI": "https://ci.nii.ac.jp/author/DA04781797"}]}]}, "item_1617186626617": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "CLT(Cross Laminated Timberクロス・ラミネイティド・ティンバー)は、挽き板(ラミナ)を層ごとに直交するように積層するように接着してパネル化した木質材料であり、欧州・北米ではCLTパネルを用いた中高層建築物について多くの事例があります。日本国内においても、CLTパネルは中高層木質建築を可能にする建材として有望視されていますが、地震国である日本においてそれを実現するためには構造設計法を新たに構築する必要があります。以上のことを背景として,CLT パネルを用いた建築物の構造設計法構築に向けたデータ収集を目的としたE-ディフェンス実験を実施しました。試験体として,5階建ての中層建築物と3階建て低層建築物の 2棟を製作,建築基準法に規定される地震動や兵庫県南部地震の観測波を入力しています。", "subitem_description_language": "ja", "subitem_description_type": "Abstract"}, {"subitem_description": "CLT (Cross Laminated Timber) is a wood-based material created by bonding layers of sawn boards (laminas) at right angles to each other to form panels. In Europe and North America, there are numerous examples of mid- to high-rise buildings constructed using CLT panels. In Japan as well, CLT panels are regarded as a promising building material for enabling mid-to-high-rise wooden buildings; however, to realize this in earthquake-prone Japan, it is necessary to establish new structural design methods. In light of the circumstances described above, an E-Defense experiment was conducted to collect data aimed at developing structural design methods for buildings using CLT panels. Two test structures were constructed: a five-story mid-rise building and a three-story low-rise building. Earthquake motions specified by the Building Standards Law and observed seismic motions from the Hyogo-ken Nanbu earthquake were input into the structures.", "subitem_description_language": "en", "subitem_description_type": "Abstract"}, {"subitem_description": "データ取得:2015年 ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "Data acquisition period : 2015", "subitem_description_language": "en", "subitem_description_type": "Other"}, {"subitem_description": "お問い合わせ:asebi@bosai.go.jp ", "subitem_description_language": "ja", "subitem_description_type": "Other"}, {"subitem_description": "inquiry: asebi@bosai.go.jp", "subitem_description_language": "en", "subitem_description_type": "Other"}]}, "item_1617186643794": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_1522300295150": "ja", "subitem_1522300316516": "防災科学技術研究所"}, {"subitem_1522300295150": "en", "subitem_1522300316516": "National Research Institute for Earth Science and Disaster Resilience"}]}, "item_1617186660861": {"attribute_name": "Date", "attribute_value_mlt": [{"subitem_1522300695726": "Issued", "subitem_1522300722591": "2017"}]}, "item_1617186783814": {"attribute_name": "識別子", "attribute_value_mlt": [{"subitem_identifier_type": "DOI", "subitem_identifier_uri": "10.17598/NIED.0020-E201402"}]}, "item_1617258105262": {"attribute_name": "Resource Type", "attribute_value_mlt": [{"resourcetype": "dataset", "resourceuri": "http://purl.org/coar/resource_type/c_ddb1"}]}, "item_1617353299429": {"attribute_name": "関連情報", "attribute_value_mlt": [{"subitem_1522306207484": "isIdenticalTo", "subitem_1522306287251": {"subitem_1522306382014": "URI", "subitem_1522306436033": "https://asebi.bosai.go.jp/"}, "subitem_1523320863692": [{"subitem_1523320867455": "en", "subitem_1523320909613": "LOGIN Page for Registered Users"}]}]}, "item_title": "CLTパネルを用いた建築物の構造性能検証震動台実験", "item_type_id": "40006", "owner": "7", "path": ["1749778844647"], "permalink_uri": "https://nied-repo.bosai.go.jp/records/7208", "pubdate": {"attribute_name": "PubDate", "attribute_value": "2025-06-19"}, "publish_date": "2025-06-19", "publish_status": "0", "recid": "7208", "relation": {}, "relation_version_is_last": true, "title": ["CLTパネルを用いた建築物の構造性能検証震動台実験"], "weko_shared_id": -1}
  1. 研究データ
  2. ASEBI

CLTパネルを用いた建築物の構造性能検証震動台実験

https://nied-repo.bosai.go.jp/records/7208

DOI

https://doi.org/10.17598/NIED.0020-E201402
https://nied-repo.bosai.go.jp/records/7208
6a1aa002-d5d9-431e-907c-3f6fd74633ca
Item type データセット / Dataset(1)
タイトル
タイトル CLTパネルを用いた建築物の構造性能検証震動台実験
言語 ja
タイトル
タイトル Shaking Table Testing to verify the Seismic Performance of CLT Buildings
言語 en
作成者 防災科学技術研究所

× 防災科学技術研究所

WEKO 1632
CiNii DA04781797

ja 防災科学技術研究所

ja-Kana ボウサイカガクギジュツケンキュウショ

en National Research Institute for Earth Science and Disaster Resilience

Search repository
内容記述
内容記述タイプ Abstract
内容記述 CLT(Cross Laminated Timberクロス・ラミネイティド・ティンバー)は、挽き板(ラミナ)を層ごとに直交するように積層するように接着してパネル化した木質材料であり、欧州・北米ではCLTパネルを用いた中高層建築物について多くの事例があります。日本国内においても、CLTパネルは中高層木質建築を可能にする建材として有望視されていますが、地震国である日本においてそれを実現するためには構造設計法を新たに構築する必要があります。以上のことを背景として,CLT パネルを用いた建築物の構造設計法構築に向けたデータ収集を目的としたE-ディフェンス実験を実施しました。試験体として,5階建ての中層建築物と3階建て低層建築物の 2棟を製作,建築基準法に規定される地震動や兵庫県南部地震の観測波を入力しています。
言語 ja
内容記述
内容記述タイプ Abstract
内容記述 CLT (Cross Laminated Timber) is a wood-based material created by bonding layers of sawn boards (laminas) at right angles to each other to form panels. In Europe and North America, there are numerous examples of mid- to high-rise buildings constructed using CLT panels. In Japan as well, CLT panels are regarded as a promising building material for enabling mid-to-high-rise wooden buildings; however, to realize this in earthquake-prone Japan, it is necessary to establish new structural design methods. In light of the circumstances described above, an E-Defense experiment was conducted to collect data aimed at developing structural design methods for buildings using CLT panels. Two test structures were constructed: a five-story mid-rise building and a three-story low-rise building. Earthquake motions specified by the Building Standards Law and observed seismic motions from the Hyogo-ken Nanbu earthquake were input into the structures.
言語 en
内容記述
内容記述タイプ Other
内容記述 データ取得:2015年
言語 ja
内容記述
内容記述タイプ Other
内容記述 Data acquisition period : 2015
言語 en
内容記述
内容記述タイプ Other
内容記述 お問い合わせ:asebi@bosai.go.jp
言語 ja
内容記述
内容記述タイプ Other
内容記述 inquiry: asebi@bosai.go.jp
言語 en
出版者
言語 ja
出版者 防災科学技術研究所
出版者
言語 en
出版者 National Research Institute for Earth Science and Disaster Resilience
日付
日付タイプ Issued
日付 2017
資源タイプ
資源タイプ dataset
資源タイプ識別子 http://purl.org/coar/resource_type/c_ddb1
識別子
識別子 10.17598/NIED.0020-E201402
識別子タイプ DOI
関連情報
関連タイプ isIdenticalTo
識別子タイプ URI
関連識別子 https://asebi.bosai.go.jp/
関連名称 LOGIN Page for Registered Users(en)
戻る
0
views
See details
Views

Versions

Ver.1 2025-06-13 01:59:24.650411
Show All versions

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3

Change consent settings


Powered by WEKO3

Change consent settings